C
531
NOTE: All dimensions in inches
Order Online at:
www.AllPointsFPS.com
REPLACEMENTS BY OEM 10
54-1100, 54-1101 58-1070 58-1019 58-1000 58-1018 54-1203 58-1078 56-1428 58-1034 54-1039
CLEVELAND (Cont.)
Steam Generators (Boilers)/Steamers (Cont.)
Description Model Use OEM Number Order Number VALVE, DRAIN -
1
/2" FPT, w/Double Switch, 32CET3A, 22CET6-1, 22CGT6-1 110613 56-1428 VALVE, DRAIN SOLENOID - Asco, 250 F, 120V, N/O, 15 PSI,
1
/2" Convection Steamers: 21-CET-8, 21-CET-16, 24-CEM-48, CET-5, 21-CGA-5; Steam Generators: 24/36 CDM, 24/36 CEM (24,36,48), 24/36 CGM (200,250,300), 24/36 CSM & Other 2 Probe Units; Boilers: BRE-3, BRE-5 22221 58-1034 VALVE, DRAIN SOLENOID - Parker, 120V,
3
/4" Convection Steamers: 21-CET-8, 21-CET-16 & Where Applicable; Pressure Steamers: Where Applicable 22244 58-1078 VALVE, GAS - Honeywell, Millivolt LP/Nat 3 Probe Boilers w/2, 3, or 4 Burners 22182 22096 54-1039 VALVE, GAS - Honeywell, 24V, Nat 36/42 GMK 11/1/K, 24/36CSM/CDM 22228 54-1061 VALVE, GAS CONTROL - LP 2DE, 2DE24, 2DG, 2DG24, 2DLE, 2DLG, 2DLLE, 2DLLG, 2DQTE, 2DQTG, 2DQTLE, 2DQTLG, 2DQTLLE, 2DQTLLG, 2DQTS, 2DQTSC, 2DS, 2DS24, 2DSC, 2DSC24, PDL-(2J,2K,3J,3K), PDM-(2J,2K,3J,3K), PDP-(2J,2K,3J,3K), PEM160-(2J,3J), PEM200-(2J,3J), PEM24-(2J,2K,3J,3K), PEM250-(2J,3J), PEM300-(2J,3J), PEM36-(2J,2K,3J,3K), PEM48-(2J,2K,3J,3K), PGM160-(2K,3K), PGM200-(2K,3K), PGM250-(2K,3K), PGM300-(2K,3K), PSM-(2J,2K,3J,3K) 22183 54-1203 VALVE, GAS - Honeywell, 24V, Nat 24CGA10 FK113048 54-1100 VALVE, GAS - Honeywell, 24V LP 24CGA10 FK113049 54-1101 VALVE, GAS SAFETY - Honeywell, LP, 24V, Gas In/Out:
3
/4" NPT, Pilot Out Only:
1
/4" CCT Boilers: 2 Probe Type Units, 24/36CGM200,250,300, 36COM16, 36CEM, 648, 36CGM16300, 36CSM16 22231 54-1078 VALVE, GAS SAFETY - Honeywell, Nat, 24V, Gas In/Out:
3
/4" NPT, Pilot Out Only:
1
/4" CCT Boilers: 2 Probe Type Units, 36COM16, 36CEM,648, 36CGM16300, 36CSM16, 24/36CGM200/250/300 22230 54-1062 VALVE, HOT WATER SOLENOID - Parker, 180 F, 120V, N/C, 150 PSI,
1
/4" Convection Steamers: 9-PCDM-L, 9-PCEM-48-L, 9-PCGM-250-L, 9-PCGM-300-L, 9-PCSM-L 22241 58-1070 VALVE, HOT WATER SOLENOID - Parker, 180 F, 120V, N/C, 100 PSI,
1
/4" Convection Steamers: 6CEM, 6CGM, 21-CET-8, 21-CET-16, 24-CGA-6.2, C, CET-5, CET-8, CET-16, 10 Pan Units; Boilers: 24CGM200, BRE-3, BRE-5; Steam Generators: Where Applicable 22218 58-1019 VALVE, HOT WATER SOLENOID - 180 F, 120/240V, N/C, 150 PSI,
1
/2", Parker Gas Steam Generators: 3 Probe (3 Burner, 160,000 BTU; 4 Burner, 200,000 BTU; 5 Burner, 210,000 & 250,000 BTU; 6 Burner, 300,000 BTU); Steam Coil Generator Assy's: w/0, 1 or 3 Probes; 3 Probe Elec Steam Gen Assy's: 24KW, 36KW & 48KW (All 1968 to Present) 44095 58-1018 VALVE, HOT WATER SOLENOID - 180 F*, 120V, N/C, 100 PSI,
1
/4" (*Steam = 232 F @7 PSI), GC/ITT Convection Steamers: 9-PCDM-8, 9-PCEM-48-L, 9-PCGM-250-L, 9-PCGM-300-L, 9-PCSM-L; Steam Generators: 3 Probe Type Units 22104 NLA@OEM 58-1000 VALVE, HOT WATER SOLENOID - 225 F, 120V, N/C, 150 PSI,
1
/4", Parker (Jackes-Evans) Convection Steamers: 9-PCDM-8, 9-PCEM-48-L, 9-PCGM-250-L, 9-PCGM-300-L, 9-PCSM-L; Steam Generators: 3 Probe Type Units 22223 58-1037 VALVE, HOT WATER SOLENOID - 3-Way, 180 F, 120V, N/C, 50 PSI,
1
/4" Convection Steamers: 9-PCDM-L, 9-PCEM-48-L, 9-PCGM-250-L, 9-PCGM-300-L, 9-PCSM-L 22236 58-1149 54-1061, 54-1062, 54-1078 58-1037 58-1149
Previous Page