GENERAL USE THERMOSTATS & HI-LIMITS 1
5 Order Online at:
www.AllPointsFPS.com
NOTE: All dimensions in inches
ROBERTSHAW
Body 1 Body 2 Straight Thru Shallow Dish Mount
FD Series Thermostats are Heavy-Duty, High Capacity Gas Controls that have either Snap Throttle (FDO) or Throttle (FDTO) Valve Action - see Control Function.
Control Body Type
FD Series Thermostats & Accessories 710 Series Gas Valve/Thermostat
ROBERTSHAW
Description Model Use Temp Range (F) Bulb Capillary Order Number Gas Valve/Thermostat For LP Gas, Catering Truck, RV Usage 100-250
1
/4 x 2
1
/2 36 54-1077
THERMOSTATS & HI-LIMITS (Cont.)
Inlet/Outlet Size Nat LP
1
/4" CCT 95,000 203,000
3
/8" NPT 148,000 317,000
1
/2" NPT 161,000 344,500
Gas Capacity (BTU/Hour)
Type Valve Action Burner Flame Range Typical Application FDO Snap Throttle Full to Off Oven (150 to 550 F) FDTO Throttle Full to By-Pass Oven (Low to 550 F) FDH Snap Throttle Full to Off Oven (650 F) FDTH Throttle Full to By-Pass Oven (650 F) FDL Snap Throttle Full to Off Liquid Fryers FDTL Throttle Full to By-Pass Liquid Fryers FDS Snap Throttle Full to Off Surface Griddle FDTS Throttle Full to By-Pass Surface Griddle
Control Function
Fast Shipments for
FASTER REPAIRS
Latest Cut-off for Same Day Shipping
For additional shipping information, see page vi of this catalog.
Subject to inventory availability. Domestic Shipping only.
Previous Page