27 Order Online at:
www.AllPointsFPS.com
NOTE: All dimensions in inches
GENERAL USE GAS 2
Gas Safety Valves
54-1054, 54-1074 54-1063 54-1073 52-1133 54-1062, 54-1078 54-1040
HONEYWELL
Gas Operator Application Pressure Setting Type Order Number In Out
1
/2
3
/4 Millivolt Pilot Gas Control Nat/LP VS820A 54-1039
3
/4
3
/4 Millivolt Pilot Gas Control Nat/LP VS820A 54-1040
1
/2
1
/2 Millivolt Pilot Gas Control Nat VS820A 54-1054
1
/2
1
/2 Millivolt Pilot Gas Control LP VS820A 54-1074
3
/4
3
/4 Thermocouple Pilot Gas Control Nat .9 Step V800C 54-1063
1
/2
1
/2 24V Dual Intermittent Pilot Gas Nat/LP VR8204A 54-1055
1
/2
1
/2 24V Dual Intermittent Pilot Gas Nat/LP VR8204A 52-1133
1
/2
3
/4 24V Dual Intermittent Pilot Gas Nat/LP VR8304M 54-1060
1
/2
3
/4 120V Dual Intermittent Pilot Gas Nat/LP VR4304M 54-1059
3
/4
3
/4 24V Direct IGN Dual Auto, Hot Surface/Spark System Nat .9 Step VR8305P 54-1062
3
/4
3
/4 24V Direct IGN Dual Auto, Hot Surface/Spark System LP VR8305P 54-1078
1
/2
3
/4 24V Direct IGN Dual Auto, Hot Surface/Spark System Nat 1.2 Step VR8305P 54-1061
3
/4
3
/4 120V Thermocouple Pilot Gas Control Valve Nat V400A 54-1079
1
/2
1
/2 24V Nat/LP VR8205A 54-1073 Comes with: (1)
1
/2" x
3
/8" Reducer and (2)
3
/4" x
1
/2" Reducers
HONEYWELL
Description Model Use Convert To Order Number VALVE CONVERSION KIT VR4200, VR4300, VR8200, VR8300 LP 51-1227 VALVE CONVERSION KIT VR4200, VR4300, VR8200, VR8300 Nat 51-1228 VALVE CONVERSION KIT V800, VS820, VS821 LP 51-1270 VAVLE CONVERSION KIT V800, VS820, VS821 Nat 51-1271 Note: VR Series Safeties ending in P can not be converted. 51-1228 51-1270 51-1271 51-1227 54-1039 54-1055 54-1060 54-1059 54-1061 54-1079
Gas Valve Conversion Kits
GAS (Cont.)